All Categories ductless-mini-split — Daikin 15 and 19 Series furnace — York YP9C modulating condensing gas furnaces documented in the York installation manual controls-thermostats — ATW-RTU room thermostats paired with ATW-IOT-01 on Yutaki systems ductless-mini-split — Gree residential mini-splits that publish E5 in the protection code family controls-thermostats — Bryant Evolution communicating systems using the Evolution Connex control and a four-conductor communication bus controls-thermostats — Google Nest Learning Thermostat and Nest Thermostat furnace — York Affinity YP9C modulating condensing furnaces and the TP9C, CP9C and LP9C models sharing the same installation manual boiler — Baxi and Potterton domestic boilers that display E119 controls-thermostats — Google Nest thermostats covered by the E-code power guide controls-thermostats — Google Nest learning and programmable thermostats that report power and delay conditions on screen ductless-mini-split — Mitsubishi Electric indoor units publishing the P-series fault table, including M-Series wall units and Mr Slim indoor equipment heat-pump — XP17 heat pumps with iComfort communicating controls ductless-mini-split — MRCOOL DIY mini-split generations that report an inverter compressor drive fault ductless-mini-split — Panasonic wall-mounted split systems that report H-series and F-series self-diagnosis codes heat-pump — Altherma 3 R MT with ELBH-E or ELBX-E and ERRA08-12 furnace — Rheem residential gas furnaces covered by the published technical FAQ furnace — R96V communicating condensing gas furnaces ductless-mini-split — Daikin indoor units covered by the SM-TS3 malfunction chart, including room air, SkyAir, and VRV indoor equipment ductless-mini-split — WindFree 3.0 AR C ductless-mini-split — Bosch Climate 5000 ductless mini-split systems documented in the Bosch service and manual library ductless-mini-split — BMKH floor-ceiling indoor units ductless-mini-split — Midea wall-split systems, and systems built on the same platform sold under other names, that publish E2 furnace — Goodman GMVC-series two-stage variable-speed gas furnaces documented in the installation and operating instructions boiler — Vaillant ecoTEC gas boilers covered by the Vaillant United Kingdom fault code list ductless-mini-split — Diamante and Quantum systems in the manufacturer code list ductless-mini-split — Mitsubishi Electric indoor units that publish the P-series protection table, including Mr Slim cassette, ducted, and ceiling-suspended indoor units heat-pump — LG residential air conditioners covered by the United States help-library article grouping these codes as outdoor compressor or circuit board problems ductless-mini-split — Daikin indoor units covered by the SM-TS3 malfunction code chart, spanning room air, SkyAir, and VRV indoor equipment multi-zone — LG multi-split systems where several indoor units share a single outdoor unit, as described in LG help-library guidance ductless-mini-split — LG single-zone systems in MFL41161610 ductless-mini-split — Senville LETO Series ductless-mini-split — Diamante Essenza, Diamante Pro, Quantum Fresh, Hyperformance, and Ultra heat-pump — Stiebel Eltron WPL air source heat pumps commissioned through the manufacturer parameter set ductless-mini-split — Hisense residential split air conditioners documented in the Hisense service and document library boiler — Vaillant ecoTEC gas boilers covered by the published United Kingdom fault code list ductless-mini-split — Midea residential split air conditioners covered by the Midea online troubleshooting code reference heat-pump — Gree residential inverter systems covered by the OEM guide furnace — Carrier deluxe two-stage gas-fired induced-combustion furnaces with PSC or ICM blower motors, per troubleshooting guide 58-3T ductless-mini-split — Della ductless mini-split systems documented in the Della manual and support library Dishwasher LaserJet Printer ductless-mini-split — Mr Slim families covered by Mitsubishi Electric's P8 reference ductless-mini-split — Multi21+ and documented residential mini-splits ductless-mini-split — Daikin multi-split systems and splits that publish UF for a wiring and piping combination fault boiler — Ideal Logic and Vogue gas boilers using the F-series and L-series fault codes published by Ideal Heating ductless-mini-split — Daikin split and multi-split systems that publish UA for an indoor and outdoor combination fault ductless-mini-split — MRCOOL DIY ductless systems across the third, fourth, and fifth generations documented in MRCOOL support air-handler — Goodman and Amana variable-speed air handlers with an integrated control module reporting motor codes on a seven-segment display and through a ComfortNet thermostat controls-thermostats — ecobee smart thermostats with installer settings governing staging, thresholds, and equipment lockouts controls-thermostats — Drayton Wiser multi-zone heating systems using a heat hub with room thermostats and smart radiator thermostats ductless-mini-split — MRCOOL single-zone and multi-zone families in official support ductless-mini-split — Gree residential mini-split indoor units using the F-series sensing bulb codes described in Gree North America support boiler — Ideal Logic, Logic Max, and Logic Plus boilers that display F1 Air Conditioner heat-pump — Mitsubishi Electric outdoor units publishing the U-series fault table, including M-Series and MXZ multi-zone outdoor equipment boiler — Ideal Logic and Logic Max boilers covered by the published fault code guidance ductless-mini-split — Econo IF, Vario TL, and Optima TP single zone, and the multi-zone systems sharing the table ductless-mini-split — Daikin room air conditioner splits and multi-split systems that publish U0 in the malfunction code table controls-thermostats — tado Smart Radiator Thermostat V3+ and earlier devices in the cited support flow ductless-mini-split — Panasonic room air conditioners with the self-diagnosis function described in Panasonic service documentation ductless-mini-split — LG single-zone systems in general service manual MFL41161610 ductless-mini-split — Sophia multi-zone cassette indoor units furnace — GMVC80 condensing gas furnaces boiler — Ariston Clas gas boilers whose fault codes are grouped by leading digit in the Ariston user documentation furnace — Carrier two-stage and variable-speed modulating condensing furnaces that report status code 31 furnace — Goodman and Amana gas furnaces with an integrated ignition control that flashes seven for low flame signal furnace — Affinity YP9C modulating gas furnaces boiler — Viessmann Vitodens gas condensing boilers whose displayed fault codes are listed in the Viessmann fault checker ductless-mini-split — Mitsubishi Electric indoor units that publish the P-series fault table, covering Mr Slim and M-Series indoor equipment ducted-split — Carrier Infinity System Control paired with communicating equipment, with the outdoor-unit code structure documented for 24VNA6 and 25VNA4 variable-speed units heat-pump — Midea residential split air conditioners and heat pumps covered by the Midea online troubleshooting code reference ductless-mini-split — LG residential air conditioners covered by the United States help-library article that groups these codes as sensor problems furnace — Ruud gas furnaces whose integrated controls report diagnostics through a blinking indicator, including the R96T range boiler — Greenstar Si Compact ErP furnace — R96T two-stage communicating condensing furnaces controls-thermostats — Lennox iComfort communicating thermostats and the equipment controls they are paired with boiler — Worcester Bosch Greenstar boilers that pair E9 with cause code 219 ductless-mini-split — Samsung indoor air conditioner units whose display shows the reminder and operating-mode characters described in Samsung support ductless-mini-split — Econo, Vario, Optima, Motto, and Umbra mini-splits heat-pump — Hitachi Yutaki air-to-water heat pump systems documented in the Hitachi air-to-water installation and operation manuals heat-pump — NIBE air source and ground source heat pumps with controllers that store an alarm log and operating history boiler — Current ecoTEC plus boilers covered by manual 0020308121-04 ductless-mini-split — Pioneer Diamante and Quantum ductless systems whose code lists are published in Pioneer support ductless-mini-split — Panasonic reverse-cycle wall split systems that report F11 in the self-diagnosis table air-handler — Trane air handlers and indoor coils fitted with a condensate overflow switch, as described in Trane homeowner support boiler — Ariston Clas ONE, Clas System ONE, and Alteas ONE boilers showing 108 ductless-mini-split — KSIV Series ductless-mini-split — Senville ductless mini-split systems across the Aura, Leto, and earlier series documented in Senville support ductless-mini-split — Toshiba residential and light-commercial systems fitted with a wired remote controller controls-thermostats — Rheem and Ruud EcoNet communicating systems in which a smart thermostat or control center shares a four-wire network with indoor and outdoor equipment boiler — Logic Max Combi boilers in manual 237660 A01 ductless-mini-split — GE Zoneline packaged terminal air conditioners and heat pumps documented in GE Appliances owner and support material ductless-mini-split — Mitsubishi Heavy Industries room air conditioners documented in the MHI user manual library controls-thermostats — tado Smart Radiator Thermostat furnace — Trane gas furnaces whose integrated control proves flame by rectification, as described in Trane homeowner support for a burner that shuts off after ignition ductless-mini-split — Fujitsu General residential indoor units that report faults through operation and timer indicator lamps heat-pump — Yutaki hydronic heat-pump systems ductless-mini-split — Klimaire ductless mini-split systems documented in the Klimaire service and support library heat-pump — F2120 air-to-water heat pumps heat-pump — Daikin outdoor units covered by the SM-TS3 malfunction chart, including room air, SkyAir, and VRV outdoor equipment Washing Machine furnace — York YP9C, TP9C, CP9C, and LP9C furnaces covered by the cited manual ductless-mini-split — Mitsubishi Electric Mr Slim and M-Series systems that publish the P-series protection table multi-zone — LG multi-split systems where several indoor units share one outdoor unit controls-thermostats — tado smart thermostat systems using a wireless receiver or an extension kit between the control and the heating appliance ductless-mini-split — TCL residential split air conditioners documented in the TCL product download library ductless-mini-split — Hi-Ultra Xtreme R-454B furnace — Carrier deluxe two-stage gas-fired induced-combustion furnaces with PSC or ICM blower motors, as covered by troubleshooting guide 58-3T heat-pump — Daikin outdoor equipment covered by the SM-TS3 malfunction chart, spanning room air, SkyAir, and VRV outdoor units ductless-mini-split — Mitsubishi Electric M-Series and Mr Slim systems that publish the E-series communication table ductless-mini-split — Forward Series systems in the manufacturer service manual boiler — Clas One and Clas System One condensing gas boilers ductless-mini-split — Climate 5000 Generation 3 R-454B multi-zone ductless-mini-split — KSIO series systems in the manufacturer troubleshooting manual furnace — Goodman and Amana single-stage and two-stage gas furnaces with an integrated ignition control boiler — Vaillant ecoTEC plus and ecoTEC sustain boilers that list F.22 ductless-mini-split — Daikin indoor units covered by the SM-TS3 malfunction chart, where the C division covers sensor systems furnace — Rheem R96V modulating condensing gas furnaces documented in the Rheem service literature ductless-mini-split — Senville systems covered by the manufacturer EC 51 support article ductless-mini-split — Cooper and Hunter ductless mini-split systems documented in the Cooper and Hunter support library furnace — S9V2 S-Series two-stage condensing gas furnaces ductless-mini-split — Forward Series light-commercial — SkyAir RZR-P and RZQ-P(9) light-commercial — Amana PTAC models covered by the M70 service procedure ductless-mini-split — MRCOOL mini-splits covered by official P0/PC00 support furnace — Carrier 58MCB Series 110 and 120 condensing gas furnaces ductless-mini-split — LETO and AURA models using an applicable AC fan motor boiler — Baxi domestic gas boilers using the E-series fault codes listed in Baxi support material ductless-mini-split — MRCOOL generations and models identified in official support furnace — Goodman GMVC80 condensing gas furnaces heat-pump — Grant Aerona air source heat pumps documented in the Grant fault and support material heat-pump — Ecodan FTC5 cylinder units, EHPT20X-MHCW and EHST20(D)(C)-MHCW boiler — Vitodens 100-W heat-only boilers in the cited UK installation instructions multi-zone — Climate 5000 Generation 3 R-454B multi-zone outdoor units heat-pump — Trane TruComfort variable-speed outdoor units on ComfortLink II communicating controls, including the XV20i heat pump ductless-mini-split — Amana packaged terminal air conditioners and heat pumps covered by the Amana PTAC service literature controls-thermostats — Honeywell Home T6 programmable thermostats configured through installer setup parameters controls-thermostats — Lennox communicating systems on iComfort S30, E30 and compatible displays, covering furnaces, air handlers, outdoor units, equipment interface modules and iHarmony zoning heat-pump — Daikin equipment covered by the SM-TS3 malfunction chart, where the U division reports system-level conditions across room air, SkyAir, and VRV furnace — Goodman GMVC-series and related integrated furnace controls documented in the installation and operating instructions heat-pump — Mitsubishi Electric inverter outdoor units publishing the U-series fault table, including M-Series single-zone and MXZ multi-zone equipment controls-thermostats — Hive heating control systems using a hub, a thermostat, and a boiler receiver as described in Hive support multi-zone — Multi21+ and the residential ranges in the Gree code overview ductless-mini-split — Discontinued Quantum WYS, CYB, RYB, UYB, and FYB heat-pump — Daikin Altherma air-to-water heat pump systems serving space heating and a domestic hot water cylinder furnace — American Standard gas furnaces whose integrated controls retain a stored fault history alongside the current status boiler — Baxi domestic boilers covered by the manufacturer E133 guidance ductless-mini-split — Blueridge BMKH ductless mini-split systems documented in the Blueridge manual library ductless-mini-split — Aurora Xtreme Inverter 36,000 BTU cooling-only 220 V heat-pump — Aquarea air-to-water heat pumps ductless-mini-split — Samsung indoor air conditioner units that display the C1 group of service codes described in Samsung support material furnace — Carrier deluxe two-stage gas-fired induced-combustion furnaces with PSC or ICM blower motors, covered by troubleshooting guide 58-3T ductless-mini-split — Toshiba air conditioning equipment using the fault code tables published in the Toshiba United Kingdom technical handbook ductless-mini-split — Haier residential split air conditioners documented in the Haier service and resource library boiler — Worcester Bosch Greenstar gas boilers using the two-part display and fault code convention described in Worcester service instructions ductless-mini-split — Friedrich Floating Air ductless indoor units documented in the Friedrich product resource library
77 / 78 ProfessionalRequired
Hitachi • controls-thermostats — ATW-RTU room thermostats paired with ATW-IOT-01 on Yutaki systems

Hitachi Yutaki alarms 77 and 78: the radio link, not the heat pump

Both alarms are about communication rather than heating. Alarm 77 means the Yutaki unit has lost communication with the ATW-IOT-01 interface, and alarm 78 means communication between ATW-IOT-01 and the ATW-RTU-12 thermostat has failed. Applies to: ATW-RTU room thermostats paired with ATW-IOT-01 on Yutaki systems These alarm numbers belong to the ATW-RTU room thermostat and the ATW-IOT-01 interface on Yutaki systems, as published in the Hitachi installation and operation manual for those controls. Yutaki units raise their own alarms in their own numbering, and a number seen on a wired controller is not necessarily the same number seen on the room thermostat. Owner-safe checks: Record the alarm exactly, including any decimal, and note which display you read it on. | Confirm the ATW-IOT-01 interface is powered, which is the first check the manual lists for both alarms. | Note whether anything changed in the property recently, such as a new appliance, a partition, or a repositioned thermostat. Qualified technician: Wiring integrity, wire loops, and interference sources on the Yutaki to interface link are installer work rather than owner checks. | A repeating alarm 78.1 is assigned to the room thermostat hardware and the manufacturer response is replacement, which should be arranged rather than attempted.

Refer to qualified technician View Guide →